{"slug":"emf-2140-2-8","name":"EMF 2140-2-8","family":"EMF","family_name":"EMF","locale":"fi","url":"https://heat-pumps-step3.prisme-proxy.com/products/emf-2140-2-8?locale=fi","refrigerant":"R290","compressor_type":"Scroll","specifications":[{"key":"application","value":["cooling","DHW","heating","high temperature"],"unit":null,"quantity_type":null},{"key":"capacity_control","value":"Frequency controlled","unit":null,"quantity_type":null},{"key":"certification","value":"CE","unit":null,"quantity_type":null},{"key":"commissioned_weight","value":650,"unit":"kg","quantity_type":"mass","canonical_value":650,"canonical_unit":"kg","conversion_available":true},{"key":"compressor_type","value":"Scroll","unit":null,"quantity_type":null},{"key":"datasheet_provenance","value":{"schema_version":1,"source_url":"https://heatpumps.energymachines.com/uploads/Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","shared_models":["emf-2140-2-8"],"revision_printed":"V3.0","date_printed":"2026-03-06"},"unit":null,"quantity_type":null},{"key":"energy_source","value":["ground","waste heat","water"],"unit":null,"quantity_type":null},{"key":"gwp","value":0.02,"unit":null,"quantity_type":null,"canonical_value":0.02,"canonical_unit":null,"conversion_available":false},{"key":"h","value":1743,"unit":"mm","quantity_type":"length","canonical_value":1743,"canonical_unit":"mm","conversion_available":true},{"key":"high_condenser_outlet_temp","value":77,"unit":"°C","quantity_type":"temperature","canonical_value":77,"canonical_unit":"c","conversion_available":true},{"key":"highest_evaporator_outlet_temp","value":25,"unit":"°C","quantity_type":"temperature","canonical_value":25,"canonical_unit":"c","conversion_available":true},{"key":"highest_heating_temperature_at_lowest_source","value":80,"unit":"°C","quantity_type":"temperature","canonical_value":80,"canonical_unit":"c","conversion_available":true},{"key":"l","value":1050,"unit":"mm","quantity_type":"length","canonical_value":1050,"canonical_unit":"mm","conversion_available":true},{"key":"lowest_evaporator_temp_to_reach_highest_condenser_temp","value":-10,"unit":"°C","quantity_type":"temperature","canonical_value":-10,"canonical_unit":"c","conversion_available":true},{"key":"lowest_inlet_temperature","value":-20,"unit":"°C","quantity_type":"temperature","canonical_value":-20,"canonical_unit":"c","conversion_available":true},{"key":"nominal_cooling","value":124,"unit":"kW","quantity_type":"power","canonical_value":124,"canonical_unit":"kw","conversion_available":true},{"key":"nominal_cooling_cop","value":3.38,"unit":null,"quantity_type":null,"canonical_value":3.38,"canonical_unit":null,"conversion_available":false},{"key":"nominal_cop_heating","value":2.68,"unit":null,"quantity_type":null,"canonical_value":2.68,"canonical_unit":null,"conversion_available":false},{"key":"nominal_heat","value":107,"unit":"kW","quantity_type":"power","canonical_value":107,"canonical_unit":"kw","conversion_available":true},{"key":"rating_points","value":{"schema_version":1,"units":{"temperature":"°C","thermal_capacity":"kW","electrical_input":"kW","compressor_speed":"Hz","cop":"1"},"points":[{"rating_point_id":"heating-standard-30hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":30,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":11,"electrical_input_kw":null,"electrical_input_boundary":"","cop":null,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"cop: not stated at 30 Hz; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"heating-standard-60hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":60,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":null,"electrical_input_kw":null,"electrical_input_boundary":"","cop":2.93,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"heating_capacity_kw,cooling_capacity_kw: sheet gives only 30–140 Hz range endpoints; no 60 Hz capacities; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"heating-standard-140hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":140,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":107,"electrical_input_kw":null,"electrical_input_boundary":"","cop":2.68,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-30hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":30,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":14,"electrical_input_kw":null,"electrical_input_boundary":"","cop":null,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"cop: not stated at 30 Hz; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-60hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":60,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":null,"electrical_input_kw":null,"electrical_input_boundary":"","cop":4.42,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"heating_capacity_kw,cooling_capacity_kw: sheet gives only 30–140 Hz range endpoints; no 60 Hz capacities; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-140hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":140,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":124,"electrical_input_kw":null,"electrical_input_boundary":"","cop":3.38,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."}]},"unit":null,"quantity_type":null},{"key":"refrigerant","value":"R290","unit":null,"quantity_type":null},{"key":"safety_class","value":"A3","unit":null,"quantity_type":null},{"key":"special_features","value":"High capacity control range","unit":null,"quantity_type":null},{"key":"use_case","value":["commercial building","industry"],"unit":null,"quantity_type":null},{"key":"w","value":795,"unit":"mm","quantity_type":"length","canonical_value":795,"canonical_unit":"mm","conversion_available":true}],"excerpt":null,"body":"EMF-lämpöpumpuissa on kaksi kylmäainepiiriä, joissa kummassakin on scroll-kompressori. \r\r\n\r\r\nTaajuusmuuttajilla varustettuna EMF toimii laajalla tehoalueella alentaen tai nostaen tehoa tarpeen mukaisesti. \r\r\n\r\r\nKaksi kylmäainepiiriä ovat toisistaan täysin riippumattomia varmistaen lämmöntuoton pysyvyyden. \r\r\n\r\r\nEMF-lämpöpumput on tarkoitettu erityisesti lämmitys- ja jäähdytyssovelluksiin.  \r\r\n\r\r\nEMF:n kylmäainetäytös on alle 5 kg piiriä kohden, mikä mahdollistaa sen joustavan sijoittamisen. \r\r\n\r\r\nSisäsäänrakennetuilla säätöventtiileillä ja liuospumpuilla varustettu EMF on täydellinen kylmä- ja lämpöpumppu yhdessä ja samassa laitteessa.","measurement_system":"metric","media":[{"url":"https://heat-pumps-step3.prisme-proxy.com/uploads/EMF-2140-2-8_pos1_25110501.jpg","alt":"EMF heat pump with dark front panel and exposed side connections","role":"gallery"}],"rating_conditions":{"schema_version":1,"units":{"temperature":"°C","thermal_capacity":"kW","electrical_input":"kW","compressor_speed":"Hz","cop":"1"},"points":[{"rating_point_id":"heating-standard-30hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":30,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":11,"electrical_input_kw":null,"electrical_input_boundary":"","cop":null,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"cop: not stated at 30 Hz; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"heating-standard-60hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":60,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":null,"electrical_input_kw":null,"electrical_input_boundary":"","cop":2.93,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"heating_capacity_kw,cooling_capacity_kw: sheet gives only 30–140 Hz range endpoints; no 60 Hz capacities; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"heating-standard-140hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"heating","source_fluid":"ethanol 26%","source_inlet_c":1,"source_outlet_c":-3,"sink_fluid":"water","sink_inlet_c":47,"sink_outlet_c":53,"compressor_speed_hz":140,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":107,"electrical_input_kw":null,"electrical_input_boundary":"","cop":2.68,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-30hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":30,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":14,"electrical_input_kw":null,"electrical_input_boundary":"","cop":null,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"cop: not stated at 30 Hz; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-60hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":60,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":null,"electrical_input_kw":null,"electrical_input_boundary":"","cop":4.42,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"heating_capacity_kw,cooling_capacity_kw: sheet gives only 30–140 Hz range endpoints; no 60 Hz capacities; electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."},{"rating_point_id":"cooling-standard-140hz","datasheet_file":"Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf","datasheet_revision":"V3.0","datasheet_date":"2026-03-06","mode":"cooling","source_fluid":"ethanol 26%","source_inlet_c":15,"source_outlet_c":10,"sink_fluid":"water","sink_inlet_c":37,"sink_outlet_c":43,"compressor_speed_hz":140,"load_point":"","configuration":"standard","subcooler_inlet_c":null,"subcooler_outlet_c":null,"thermal_capacity_kw":124,"electrical_input_kw":null,"electrical_input_boundary":"","cop":3.38,"cop_scope":"not_stated","publication_status":"reported_with_missing_duty_electrical_input","missing_reasons":"electrical_input_kw,electrical_input_boundary: duty input and boundary not stated; page 3 rated power input is an electrical sizing specification, not mode-specific duty input; load_point: not stated; standard: no performance test standard stated; CE is certification, not a rating standard","notes":"30 and 140 Hz capacities are mapped from printed 30–140 Hz range endpoints; endpoint interpretation is explicit and requires EM confirmation if used for a performance guarantee."}]},"shared_content":{"software":"**EM Control**\r\n*Saumaton ohjaus ja automaatio*\r\nKaikki Energy Machines -lämpöpumput on varustettu Energy Machinesin EM Control -ohjausjärjestelmällä. EM Control sisältää paikallisen laitteiston ja sulautetun ohjelmiston rakennusten ja teollisuusprosessien valvontaan, ohjaukseen ja automaatioon. Nämä ominaisuudet laajenevat täydellisen etähallinnan tarjoavalla EM Cloudilla.\r\n\r\n**EM Cloud**\r\n*Joustava optimointi mistä tahansa*\r\nEM Control sisältää pilvipohjaisen visuaalisen EM Cloud -sovellusalustan energiajärjestelmän hallintaan. EM Cloudin sisältämä SCADA/HMI-ohjelmisto tarjoaa pilvipohjaisen näkymän ohjausjärjestelmän dataan ja suorituskykyyn. Käyttäjät voivat kerätä rakennuksen reaaliaikaista energiadataa, antaa komentoja PLC:ille, säätölaitteille tai muille laitteille, ohjatakseen lämpöpumppuja tai energiajärjestelmää tarpeiden mukaisesti varmistaen, ettei energiaa hukata. Jatkuva valvonta ja tiedon tallennus tarjoavat optimointimahdollisuuksia täydellä etähallinnalla.\r\n\r\n*(Valinnainen lisäosa)*\r\n**EM Verify**\r\n*Lämpöpumpun suorituskyvyn läpinäkyvyys*\r\nEM Cloudin valinnainen lisäosa EM Verify mahdollistaa lämpöpumpun suorituskyvyn reaaliaikaisen seurannan. Mittareihin kuuluvat lämpöpumpun hyötysuhde (COP), kompressorin COP, energian tuotanto, kierron tehokkuus ja ennakoivan kunnossapidon varoitusjärjestelmä. Ymmärtämällä lämpöpumpun toiminnan, EM Verify mahdollistaa käyttäjille tietoon perustuvan päätöksenteon tehokkuuden ja kustannussäästöjen optimoimiseksi.","supplementary":"**EMHW**\r\nEMHW-tuotteet on suunniteltu lämpimän käyttöveden tuottamiseen sarjaan kytketyillä lämmönvaihtimilla. Lämmönvaihtimet lämmittävät vettä (tai nestettä) vaiheittain 60°C:seen (140°F). Lämmönvaihtimet voivat hyödyntää erilaisia lämmönlähteitä.\r\n\r\nEMHW on tehdasvalmis yksikkö, jossa kaikki vaihtimien pumput ja venttiilit on esikytketty ja testattu ennen tehtaalta lähtöä, ja se vaatii vain paikan päällä tehtävät putkisto- ja sähköliitännät. Ohjausventtiileillä ja kiertovesipumpuilla varustettu laite yhdistetään energiajärjestelmään, jotta saavutetaan vaaditut lämpötilatasot.\r\n\r\nKylmäaine: EMHW ei sisällä kylmäainepiirejä.\r\nNimellinen lämmityskapasiteetti: 130-500 kW\r\n\r\n**EMCW**\r\nEMCW-tuotteet ovat samanlaisia kuin EMHW-tuotteet, mutta ne on suunniteltu veden tai nesteiden jäähdyttämiseen.\r\n\r\nEMCW on tehdasvalmis yksikkö, jossa kaikki vaihtimien pumput ja venttiilit on esikytketty ja testattu ennen tehtaalta lähtöä, ja se vaatii vain paikan päällä tehtävät putkisto- ja sähköliitännät. Varustettuna ohjausventtiileillä ja kiertovesipumpuilla varustettu laite yhdistetään energiajärjestelmään, jotta saavutetaan vaaditut lämpötilatasot.\r\n\r\nKylmäaine: EMCW ei sisällä kylmäainepiirejä.\r\nNimellinen jäähdytyskapasiteetti: Määritellään pyynnöstä"},"documents":[{"document_id":"cmojtqvar000uzqky4t5laukq","product_slug":"emf-2140-2-8","product_name":"EMF 2140-2-8","label":"Datasheet EMF-2140-2-8 V3.0, Feb 2026.pdf","doc_type":"attachment","mime_type":"application/pdf","url":"https://heat-pumps-step3.prisme-proxy.com/uploads/Datasheet_EMF-2140-2-8_V3.0__Feb_2026.pdf"}],"note":"Nominal values and individual temperature limits are screening data, not performance guarantees at your operating point. Confirm simultaneous source/supply conditions, duty, flow, fluid and redundancy with Energy Machines."}